985 resultados para Latex Hypersensitivity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article characterizes hypersensitivity reactions during anesthetic-surgical procedures. This integrative literature review was conducted in the LILACS, CINAHL, COCHRANE and MEDLINE databases including papers published from 1966 to September 2011. A total of 17 case reports, two prevalence studies and one cohort study were identified. Latex reactions were mainly type III and the primary source of intraoperative reaction was latex gloves. The average time for clinical manifestation was 59.8 minutes after anesthetic induction; 44.4% of patients reported a reaction to latex at the pre-anesthetic evaluation. It was determined that the history of allergic reactions to latex obtained in the pre-anesthetic evaluation does not ensure the safety of patients if the staff is inattentive to the severity of the issue. There is also a tendency to initially attribute the anaphylactic event to the anesthetic drugs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Os elásticos ortodônticos intermaxilares sintéticos vem sendo cada vez mais utilizados, sendo principalmente indicados para pacientes que apresentam hiper-sensibilidade ao látex. Afim de avaliar e comparar o comportamento de elásticos de látex e sintéticos quanto a perda de força ao longo do tempo, este estudo foi realizado tanto in vitro quanto in vivo. Para o estudo in vitro foram avaliados 15 elásticos de cada material, para cada tempo: 0, 1, 3, 12 e 24 horas. No estudo in vivo, pacientes foram avaliados (N=15), utilizando elásticos de ambos os materiais (látex e sintético), nos mesmos tempos do estudo in vitro. Os elásticos foram transferidos para a máquina de ensaios mecânicos (EMIC DL-500 MF). Os valores da força gerada foram registrados após a distensão dos elásticos a uma distância de 25mm. Foi aplicado o teste t pareado para a amostra clínica e independente para a amostra laboratorial. Foi utilizada a análise de variância (ANOVA) para verificar a variação das forças geradas entre os tempos determinados e o teste post-hoc para identificar entre quais tempos houve diferença significativa. Quanto às forças iniciais geradas (zero hora), os valores para os elásticos sintéticos foram bastante semelhantes entre os estudos laboratorial e clínico e ligeiramente superiores aos dos elásticos de látex. Nos tempos subsequentes, as forças geradas pelos elásticos de látex apresentaram valores superiores. Em relação à degradação do material, ao final de 24 horas, maior percentual foi observado para os elásticos sintéticos, tanto in vitro quanto in vivo. A maior queda nos valores das forças liberadas pelos elásticos de ambos os materiais e nos estudos clínico e laboratorial, ocorreu entre os tempos de 0 e 1 hora, seguida de uma queda gradativa e progressiva até o tempo de 24 horas. Os elásticos de látex apresentaram um comportamento mais estável no período estudado em relação aos sintéticos, em ambos os estudos.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUÇÃO: A alergia ao látex tornou-se um risco crescente aos indivíduos expostos, como os profissionais da área da saúde, tendo como agravo a associação com hipersensibilidade a vários alimentos, especialmente frutas. OBJETIVO: Avaliar a freqüência de sensibilização ao látex e a frutas em profissionais da área da saúde. MÉTODOS: Foram avaliados 53 profissionais da saúde, 81,9% do sexo feminino, aplicando-se questionário alergológico e testes cutâneos por puntura para alérgenos inaláveis, do látex e de frutas (mamão papaia, kiwi, abacate, banana, figo, tomate, noz). RESULTADOS: Dos 53 indivíduos estudados, 15 (28,5%) eram alérgicos ao látex. A sensibilidade a frutas foi diagnosticada em 14 (26,4%), dos quais 10 (18,8%) apresentavam teste por puntura positivo para o látex; as frutas alergênicas mais freqüentes foram papaia (80,0%), kiwi (60,0%) e abacate (50,0%). CONCLUSÃO: Estes achados demonstram a existência da alergia látex-fruta, como descrito na literatura, sendo de suma importância uma avaliação in vivo em profissionais da área de saúde, caracterizados como potencial grupo de risco.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Latex allergy is a serious, possibly life threatening health hazard in the perioperative environment. Policy and procedures should be developed to identify patients who may be sensitive to latex and to ensure the avoidance of latex products in their care. Healthcare workers should also take steps to avoid exposure and protect themselves from hypersensitivity reactions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Natural rubber latex, an aqueous colloidal dispersion of polyisoprene is widely used in production of gloves, catherers, rubber bands etc. The natural rubber latex content present in products such as gloves causes allergic problems. Of the different types of allergies reported, latex is known to produce Type I and Type IV allergies. Type I is called immediate hypersensitivity and type IV is called delayed hypersensitivity. It has been reported that some of the proteins present in the latex are mainly responsible for the allergic reactions type I. Significant reduction in the allergic response (type I) of natural rubber latex can be achieved by the reduction in its protein content, however out of the total proteins present in the latex or latex film only a fraction is extractable. The major techniques employed to reduce protein content of latex include leaching, autoclaving, chlorination, use of proteolytic enzymes and use of non ionic surfactants. Sulphur vulcanization of dipped products is responsible for Type IV allergy. N-nitrosamine, a carcinogenic substance is produced as a result of sulphur vulcanization. Radiation vulcanization can be used as an alternative for sulphur vulcanization. The current research deals with techniques to reduce the allergy associated with latex products. To reduce the type I allergy, low protein latex is developed using polyethylene glycol, a non- ionic surfactant. The present study employs radiation vulcanization to eliminate type IV allergy. The effect of different cure systems and fillers on the properties of low protein latex is also investigated as a part of the study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cross-link density, microstructure and mechanical properties of styrene butadiene rubber (SBR) composites filled with different particle sized kaolinites are investigated. With the increase of kaolinite particle size, the cross-link density of the filled SBR composites, the dispersibility and orientation degree of kaolinite particles gradually decrease. Some big cracks in filled rubber composites are distributed along the fringe of kaolinite aggregates, and the absorbance of all the absorption bands of kaolinites gradually increase with the increase of kaolinite particle size. All mechanical property indexes of kaolinite filled SBR composites decrease due to the decrease of cross-linking and reduction of interface interaction between filler and rubber matrix.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A LATEX style file, named qutthesis.sty, is developed, for writing PhD or Research Masters thesis. Developed by Professor Glen Yu-Chu Tian, it tries to fulfill QUT’s Thesis requirements but it is unofficial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rabbits and guinea pigs were immunized with functionalized aspirin-protein conjugates prepared by coupling 5-N-Succinylamino aspirin to BSA and BGG using a water soluble carbodiimide (EDC). Two populations of antibodies, one specific to functionalized aspirin and the other exclusively specific to salicylic acid were detected. These antibodies were fractionated and separated on affinity polymers suitably prepared with 5-N-succinylamino salicylic acid and 5-N-succinylamino-2-ethoxy benzoic acid as the ligands. The isolated and purified antibodies were electrophoretically homogeneous. The physico chemical interactions between the antibodies and the respective haptens were studied by radio-immunoassay, equilibrium dialysis and fluorescence quenching techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Preferential cleavage of active genes by DNase I has been correlated with a structurally altered conformation of DNA at the hypersensitive site in chromatin. To have a better understanding of the structural requirements for gene activation as probed by DNase I action, digestability by DNase I of synthetic polynucleotides having the ability to adopt B and non-B conformation (like Z-form) was studied which indicated a marked higher digestability of the B-form of DNA. Left handed Z form present within a natural sequence in supercoiled plasmid also showed marked resistance towards DNase I digestion. We show that alternating purine-pyrimidine sequences adopting Z-conformation exhibit DNAse I foot printing even in a protein free system. The logical deductions from the results indicate that 1) altered structure like Z-DNA is not a favourable substrate for DNase I, 2) both the ends of the alternating purine-pyrimidine insert showed hypersensitivity, 3) B-form with a minor groove of 12-13 A is a more favourable substrate for DNase I than an altered structure, 4) any structure of DNA deviating largely from B form with a capacity to flip over to the B-form are potential targets for the DNase I enzymic probes in naked DNA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymeric admixtures to concrete ingredients modify the properties of the processed concrete. Ductility is one such property modification. This investigation deals with the development of a method of incorporating natural rubber latex into concrete ingredients with only marginal effects on the compressive strength of base plain concrete. This retention of the strength has been effected by reducing the water/cement ratio with the aid of a superplasticizer. The quantity of natural rubber latex is expressed as the dry rubber content by percentage of volume of concrete. The compressive and tensile strengths, as well as post peak ductile behaviour have been the basis for comparison with those of unmodified concrete.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The airborne pollen of the South American weed, Parthenium hysterophorus (American feverfew), accidentally introduced into India was found to be responsible for severe allergic rhinitis. A random clinical survey conducted on 2035 residents of Bangalore city with the aid of questionnaires and skin tests revealed that 7.1% of the study population was suffering from allergic rhinitis due to exposure to Parthenium pollen. Skin-prick tests performed on 1294 clinic patients suffering from nasobronchial allergy during the past 4 years have also shown that 42.5% were sensitive to Parthenium pollen. IgE and IgG antibodies specific for Parthenium pollen allergens were demonstrable in the sera of Parthenium-sensitive rhinitis patients. The specificity of these antibodies to Parthenium allergens was established by ELISA. A 7- to 11-fold higher stimulation was observed when lymphocytes from two Parthenium-sensitive rhinitis patients were treated in vitro with Parthenium pollen extract. To our knowledge, nowhere in the world has such a high incidence of allergic rhinitis due to a single pollen ever been reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lymphocytes collected from rhinitis subjects with strong positive skin reactions to the pollen allergens of Parthenium hysterophorus (American feverfew) having moderate to high titres of Parthenium-specific serum IgE were analysed for association of HLA-antigens covering 13 specificities of HLA-A, 17 specificities of HLA-B and eight specificities of HLA-DR loci by the NIH two-stage microlymphocytotoxicity assay. Comparison of the phenotypic frequencies of HLA-A and B antigens between Parthenium rhinitis subjects (n= 22) and control subjects (n= 137) did not suggest any significant association when tested for these antigen specificities. A significant correlation in the association of HLA-DR3 antigen with a relative risk of 11·33, however, was observed in Parthenium rhinitis subjects (n= 30) when compared to controls (n= 50).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New materials in concrete constructions have been widely used to improve various properties such as impact resistance, strength and durability. Polymer modified concrete is one of the new materials which has been developed for potential application in the construction industry. This Paper describes the use of polymer latex for foundation blocks subjected to dynamic loads. Experiments were conducted using ordinary concrete and latex modified concrete footings of three different thicknesses, for three static loads at four excitation levels. Experimental results have revealed that the amplitude of resonance is reduced considerably in the latex modified concrete footings.